• Gas
  • Electric boiler
  • Solid fuel boiler
  • Sun
  • Heat pumps
  • Installation of heating element (TEN)
  • Hot water supply (HWS)
  • Capacity from 400 to 2000 liters;
  • Magnesium anode for additional anti-corrosion protection;
  • Side inspection flange;
  • Quality thermal insulation class C (ErP) with thickness of 50 mm;
  • Possible performance with tank working pressure 8 and 10 bar;
  • Hole for recirculation line.
Capacity400-2000 l
Working pressure at heat exchanger input6 bar
Working pressure at heat exchanger input10 bar
Operating temperature of the tank95 °C
Warranty5 years

TECHNICAL DESCRIPTION

The water heater is designed for heating water in bivalent systems, as well as for its accumulation and storage for DHW. The lower heat exchanger is i ntended for connection to low-temperature heat sources (e.g., solar collectors, heat pumps). The upper heat exchanger is designed for connection to high-temperature sources (primarily used for additional heating). The tank’s design includes a flanged inspection hatch with a cover, intended for periodic service maintenance of the tank. Above the lower heat exchanger, a fitting is provided for installing an electric heat element. To protect the internal coating, one or more magnesium anodes are included.

MATERIAL

The tank is made of S235JR (DIN 1.0038) carbon structural steel with an internal polycaramic coating that offers high adhesion to metal and elasticity, preventing microcracking due to thermal deformation of the tank walls. The external coating provides enhanced resistance to mechanical impacts and aggressive environments.

HEAT EXCHANGERS

The heat exchangers are made of AISI 304L (DIN 1.4307) stainless steel.

THERMAL INSULATION

PL/PVC100 mm polyester insulation in a zippered PVC casing
PU/PVC90 mm elastic polyurethane foam insulation in a PVC casing secured with straps
PL/ABS100 mm polyester insulation in an ABS plastic casing with plastic latches
PS/ABS100 mm high-efficiency rigid graphite polystyrene insulation in an ABS plastic casing.
Premium-class insulation complies with all requirements of the ErP 2009/125/EC Directive
Vof tank, l Dimensions, mm STO1, m2 VTO1, l STO2, m2 VTO2, l Mounting dimensions, mm
H ØD1 ØD Ød h1 h3 h4 h5 h6 h7 h8 h9 h10 h11 h12 h13 h14 h15 h16
400 1730 700 600 450 1,95 14 1,00 7 331 991 331 1449 1141 1241 75 1116 331 916 1216 1481 1066 456
1¼” 1¼” 1″ ¾” 1½” ½” 1″
500 1980 700 600 450 1,95 14 1,25 9 331 991 331 1687 1291 1391 75 1116 331 916 1366 1731 1066 456
1211* 1719* 1411* 1511* 1336* 1136* 1486* 1286*
1¼” 2,60* 19* 1,00* 7* 1¼” 1″ ¾” 1½” ½” 1″
750 2035 850 750 600 1,90 14 1,05 8 357 885 357 1449 1185 1285 75 1010 357 810 1260 1757 960 482
1149* 1701* 1349* 1449* 1274* 1074* 1424* 1224*
1¼” 2,95* 21* 1,40* 10* 1¼” 1″ ¾” 1½” ½” 1″
1000 2085 950 850 700 2,50 23 1,25 12 390 890 390 1440 1190 1290 75 1015 390 815 1265 1790 965 515
1090* 1690* 1290* 1390* 1215* 1015* 1365* 1165*
1½” 3,50* 32* 2,00* 19* 1½” 1¼” ¾” 1½” ½” 1″
1500 2170 1100 1000 850 2,80 26 1,55 15 430 880 430 1430 1180 1280 75 1005 430 805 1255 1830 955 1830 555
1130* 1730* 1330* 1430* 1255* 1055* 1405* 1205*
1½” 3,50* 32* 2,00* 19* 1½” 1¼” ¾” 1½” ½” 1″
2000 2260 1300 1200 1000 5,55 51 3,15 29 471 1171 471 1871 1471 1571 75 1296 471 1096 1546 1871 1246 1471 596
2″ 2″ 1¼” 1″ 1½” ½” 1″