• Gas
  • Electric boiler
  • Solid fuel boiler
  • Sun
  • Heat pumps
  • Installation of heating element (TEN)
  • Heating floor
  • Heating radiator
  • Hot water supply (HWS)
  • Stainless steel inner tank with waveform of the wall
  • The possibility of connecting of any heat generators
  • The possibility of connecting of thermoelectric heating elements
  • Capacity 400-2000 liters
  • The possibility of manufacturing of any configuration as per customer’s order
Capacity400-2000 l
Working pressure at heat exchanger input3 bar
Working pressure on the side of heating circuit6 bar
Inner tank working pressure6 bar
Operating temperature of the tank95 °C
Warranty5 years

TECHNICAL DESCRIPTION

The storage tank is designed to accumulate thermal energy from various sources, including solar collectors, via a lower heat exchanger. The internal DHW tank is located in the upper part of the tank, allowing the use of the highest-temperature heat carrier for rapid and efficient heating of DHW, as well as storing it in the required volume. The DHW reserve ensures coverage of peak hot water consumption. Thanks to its corrugated wall design, the internal tank offers sufficient resistance to external pressure fluctuations.

MATERIAL

The tank is made of S235JR (DIN 1.0038) carbon structural steel. The external coating provides enhanced resistance to mechanical impacts and aggressive environments.

INTERNAL TANK

The internal DHW tank with a corrugated (wavy) wall is made of AISI316L (DIN 1.4404) stainless steel.

HEAT EXCHANGER

The lower heat exchanger (external heating circuit) is made of C22 (DIN 1.0402) carbon steel.

THERMAL INSULATION

PL/PVC100 mm thick polyester thermal insulation in a PVC fabric casing with a zipper
PU/PVС90 mm thick elastic polyurethane foam insulation in a PVC fabric casing secured with straps
PL/ABS100 mm thick polyester thermal insulation in an ABS plastic casing with plastic latches
PS/ABS100 mm thick high-efficiency rigid thermal insulation made of graphitized polystyrene in an ABS plastic casing. Premium-class insulation - complies with all requirements of the ErP 2009/125/EC Directive
Vof tank, l Vof inner tank, l Dimensions, mm STO1, m2 VTO1, l Mounting dimensions, mm e a, b c t
H ØD1 ØD Ød h1 h2 h3 h4 h5 h6 h7 h8 h9 h12 h13
400 80 1720 800 600 450 1,5 10 264 834 1406 249 414 1256 336 248 688 ½” ¾” ½” ½”
1½” 1½” ½” ¾” ¾” 1″
500 80,115 1970 800 600 450 1,5 10 264 721 1181 1634 249 414 964 1534 336 248 688 ½” ¾” ½” ½”
185 1½” ½” ¾” 1″
750 115 2030 950 750 450 1,5 10 295 752 1212 1665 280 445 995 1565 367 279 631 ½” ¾” ½” ½”
270 1½” ½” ¾” 1¼” 1″ ¾”
1000 115 2080 1050 850 450 1,8 14 323 780 1240 1693 308 473 1023 1593 395 311 661 ½” ¾” ½” ½”
270 1½” ½” ¾” 1¼” 1″ ¾”
1500 115 2170 1200 1000 450 2,3 18 368 825 1285 1738 353 518 1068 1638 440 356 706 ½” ¾” ½” ½”
270 1½” ½” ¾” 1¼” 1″ ¾”
2000 115 2270 1400 1200 450 2,3 18 419 876 1336 1789 404 569 1119 1689 491 407 707 ½” ¾” ½” ½”
270 1½” ½” ¾” 1¼” 1″ ¾”