Tank VTA-4
  • The possibility of connecting of thermoelectric heating elements
  • Capacity 200-10000 liters
  • The possibility of manufacturing of any configuration as per customer’s order
Ask a question

Characteristics

Capacity 200-10000 l
Tank working pressure 10 bar
Working pressure at heat exchanger input 3 bar
Working pressure on the side of heating circuit 6 bar

Vof tank, l Dimensions, mm Mounting dimensions, mm
H ØD1 ØD Ød h1 h2 h3 h4 h5 h6 h7 h8 h9
200 1310 700 500 400 251 647 - 1043 236 401 - 921 323
1½"
300 1920 700 500 400 251 708 1168 1621 236 401 951 1521 323
1½"
400 1700 800 600 450 264 834 - 1406 249 414 - 1256 336
1½" 1½" ½" ¾"
500 1995 800 600 450 264 721 1181 1634 249 414 964 1534 336
1½" 1½" ½" ¾"
750 2010 950 750 600 295 752 1212 1665 280 445 995 1565 367
1½" 1½" ½" ¾"
1000 2060 1050 850 700 323 780 1240 1693 308 473 1023 1593 395
1½" 1½" ½" ¾"
1500 2150 1200 1000 850 368 825 1285 1738 353 518 1068 1638 440
1½" 1½" ½" ¾"
2000 2250 1400 1200 1000 419 876 1336 1789 404 569 1119 1689 491
1½" 1½" ½" ¾"
3000 2340 1600 1400 1150 465 922 1382 1835 450 615 1165 1735 537
2" 2" ½" ¾"
4000 2400 1800 1600 1300 490 947 1407 1860 475 640 1190 1760 562
2" 2" ½" ¾"
5000 2900 1800 1600 1300 490 1110 1740 2360 475 640 1450 2260 562
2" 2" ½" ¾"
6300 2850 2100 1900 - Configuration and size of pipes on request
8000 3600 2100 1900 -
10000 4350 2100 1900 -